Search Results

Search results for "EVRMNC35A"

11/4 Gas Solenoid Valve Manual Reset Elektrogas EVRMNC35A

11/4 inch gas safety shut off solenoid valve with manual reset Elektrogas EVRMNC35A (EVRM-NC-1/14)\nFunction: 2/2 way normally closed with manual reset, (Option Normally Open EVRMNA35A)\nOperation: direct acting\nPort: 11/4 BSP\nBody: Aluminium\nSeals: NBR based rubber certified for gas (EN549)\nClosing time: < 1 second \nCertified: EN161 Class A Group 2, CE Reg PED/0497/895/07, PED 2014/68/EU (Pressure Equipment Directive), ATEX 2014/34/EU, electromagnet compatibility 2014/30/EU, low voltage directive 2014/35/EU and RoHS II 2011/65/EU. \nPressure: 0 to 600 millibar, option (EVRM6NC35A) 6 Bar\nMedia: Air and Natural Gas and non corrosive gases families 1, 2 and 3 (EN437), option (J) Biogas free of ferrous metals with FPM sealing. \nKvs flow factor: 22 cubic meters an hour\nVoltage: 230vAC is standard, option (D) 12vAC/DC, (C) 24vAC/DC or (B)110vAC\nCoil: 12 Watt IP65 100% duty rated Class F DIN43650A (voltage tolerance -15% to +10% \nCoil option: ATEX for use in zones 2 and 22 according to 2014/34/EU ATEX directive. Category II 3 G,D, protection Ex nA IIA T4 Gc X, Ex Tc IIIB T135C Dc X or Ex Tc IIIC T135C Dc X (IP65)\nFilter: Incorporated 600 μm (0,02 in) metal mesh filter to protect valve disc and seals as well as downstream components.\nGauge ports: provided with G1/4 pressure gauge ports on both sides to connect manometers, pressure switches, leak tester or other gas equipment.\nPosition indication: G1/8 connection (Included) to fit CPI mechanical closed position switch PCS4.\n\nThe EVRM-NC-35A 11/4 valve is a manual reset safety valve that is failsafe closed. To open the valve from its closed position, the coil must be energised and the knob pulled to the fully open position. Once opened, the valve can maintain this open position whilst electric current is applied to the coil. In absence of electric current the valve closes rapidly (under 1 second) and remains shut until the reset proceedure is reapplied. Once the causes for the lock have been eliminated, valve must be opened manually as described above.\n\nAll components are designed to withstand any mechanical, chemical and thermal condition occuring during typical service. Effective impregnation and surface treatments have been used to improve mechanical reliability , sealing and corrosion resistance.\n\nValves are 100% tested by computer test machines and are fully warrented.

0 in stock Model: EVRMNC-11/4