Search Results

Search results for "VMR932"

DN125 Gas Solenoid Valve EN161 0-200mBar Auto Reset Elektrogas VMR932

5 inch Gas Solenoid Valve EN161 Elektrogas VMR932\nFunction: 2/2 way normally closed\nOperation: direct acting\nPort: 5\" DN125 PN16 flange, (Option ANSI150Lb)\nPressure: 0 to 200 millibar, options 500 millibar or 6 Bar\nMedia: Air, Natural Gas, option (J) Biogas and (K) Coke oven gas (COG)\nCertified: EN161 Class A Group 2 and CE registration 0063AQ1350 by GASTEC, SIL3 to IEC EN 61508 by Intercert certificate no. C-IT.AB86.B.04357 \nKvs flow factor: 250.0 m³/Hr, equipped with flow rate adjustment\nBody: Aluminium\nSeals: NBR based rubber certified for gas (EN549)\nOpen/close time: <1 second \nTemperature: -15°C to +60°C\nMesh filter: 600 µm protects valve seat, disc and downstream components\nGauge ports: 1/4 BSP pressure gauge ports on two sides of the inlet chamber, to connect pressure gauges, pressure switches, leakage tester or other gas equipment.\nProof of closure: 1/8BSP port to accept PCS switch fitted as standard.\nVoltage: 230vAC standard, option for 12vDC, 24vDC, 24vAC and 110vAC\nCoil: IP54 EN60529 with terminal box M20x1.5 (EN50262) and PG9 cable gland to avoid water and dirty contamination.\nElectrical safety: Class I (EN 60335-1)\nCoil: Insulation Class H 200°C, thermal resistance Class F 155°C\nVoltage tolerance: -15% to +10%\n\nCoil option: Low power coil (L), ATEX Ex-proof Zones 2 and 22, according to 94/9/EC Directive, Category II 3 G, D protection Ex n A II T4 X, Ex tD A 22 IP54 T135 X \n\nOption: Proof of closure switch (P): Mechanical closed position electrical switch PCS95.\n\nValves are 100% tested by computerised testing and are fully warranted.\n\nAll components are designed to withstand any mechanical, chemical and thermal condition occurring during typical service. Effective impregnation and surface treatments have been used to improve mechanical reliability , sealing and corrosion resistance. \n\nThe VMR932 is an auto reset fast opening single-stage solenoid valve for air or gas blocking and releasing controls, required in gas power burners, atmospheric gas boilers, furnaces and others gas consuming equipment.\n\nVMR1930.1990 230vAc coil for VMR932

2 in stock Model: VMR932

DN125 5" Safety shut off valves for gas with hydraulic actuator 0-500mBar VMH93

DN125 5 inch PN16 Flanged Gas safety shut off valve Elekrogas VMH93.\nFunction: 2/2 way normally closed\nOperation: Safety shut off valves for gas with hydraulic actuator. When energised the oil pump lifts the piston, the piston opens against the combined force of spring and gas pressure. If the power is removed , the relief valve opens quickly shutting the valve.\nActuator LED: visual LED confirmation that unit is electrically energised. \nPort: 5 inch DN125 PN16 flange ISO7005\nCertified: EN161 Class A group 2 back pressure sealing compliant for natural gas, CE Certificate 0063C01798, Gas appliance EU directive 2009/142/EC by Kiwa, PED 2014/68/UE (ex 97/23/CE) by CSI Spa.\nMedia: air and non-aggressive gases included in the 1, 2 and 3 families (EN 437), option (J) Biogas and (K) coke oven gas.\nBody: Aluminium\nSeals: NBR, FPM and PTFE\nPressure: 0 to 500 millibar. \nKvs Flow factor: 250.0 cubic meters an hour\nCPI Switch: closed position indication feed back switch (included)\nVoltage: 230vAC is standard, option 110vAC\nCoil: 20VA holding, inrush 110 Watt, \nCoil duty: 30 cycles per hour Max\nOpening time: 25 to 40 Seconds\nCoil option: ATEX Ex-proof for hazardous area zone 2 according to ATEX 94/9/EC directive.\nDuty: Qualified for continuous service (100% ED). \nProtection: IP65 DIN43650A ISO 4400 plug to EN60529\nAuxiliary ports: G1/4 pressure gauge on two sides in both inlet and outlet chamber to connect manometers, pressure switches, leakage tester or other gas equipment.\nFilter: 600μm incorporated fine mesh filter protects the valve seat and disc as well as downstream components.\n\nThe VMH93 is a safety shut off valve for gas with hydraulic actuator and are suitable for air or gas blocking and releasing controls, required in the main pipe of gas power burners, atmospheric gas boilers, industrial kilns and others gas consuming equipment.\nThe valve is open only when energized: if, for any reason, power supply goes down, the valve closes immediately (intrinsic safe), \n\nAll components are designed to withstand any mechanical, chemical and thermal condition occurring during typical service. Effective impregnation and surface treatments have been used to improve mechanical sturdiness, sealing and resistance to corrosion of the components. \nValves are 100% tested and fully warranted.\n\nOutdoor use: Please ensure that installing area is protected from rain and water splashes or drops. (See full data sheet Page 12)

1 in stock Model: VMH93